Low Cost Journal,International Peer Reviewed and Refereed Journals,Fast Paper Publication approved journal IJEDR(ISSN 2321-9939) apply for ugc care approved journal, UGC Approved Journal, ugc approved journal, ugc approved list of journal, ugc care journal, care journal, UGC-CARE list, New UGC-CARE Reference List, UGC CARE Journals, ugc care list of journal, ugc care list 2020, ugc care approved journal, ugc care list 2020, new ugc approved journal in 2020, Low cost research journal, Online international research journal, Peer-reviewed, and Refereed Journals, scholarly journals, impact factor 7.37 (Calculate by google scholar and Semantic Scholar | AI-Powered Research Tool)
INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCH
(International Peer Reviewed,Refereed, Indexed, Citation Open Access Journal)
ISSN: 2321-9939 | ESTD Year: 2013

Current Issue

Call For Papers
June 2023

Volume 11 | Issue 2
Last Date : 29 June 2023
Review Results: Within 12-20 Days

For Authors

Archives

Indexing Partner

Research Area

LICENSE

Paper Details
Paper Title
Performance Analysis of Shunt Active Power Filter with Various Switching Signal Generation Techniques
Authors
  Mr. Shashibhushan R. Shahu ,  Mr. Nikhil A. Wanjari

Abstract
ABSTRACT The performance of shunt active power filter (SAPF) is compared for steady state load condition. The SAPF is used for harmonic compensation of single phase ac/dc converter feeding a nonlinear load. The process involves an injection of equal but opposite current to mitigate the distortion current supplied back by nonlinear load to the voltage supply. Thus, the injected current will shape the supply current to a sinusoidal phase with the supply voltage. The techniques which are considered for comparative study are Hysteresis Current Control (HCC) and Sinusoidal Pulse Width Modulation (SPWM) technique. Performance analysis of above two switching signal generation based on percentage (THD) Total Harmonic Distortion, complexity speed of response, switching frequency and delay time in MATLAB. After simulation we can analyse the different results on above two methods based on given parameters of SAPF. The percentage THD of supply current reduces as per IEEE519 standard. HCC is simple in implementation over SPWM technique. The speed of response of both controllers is same. The switching frequency of HCC is variable but the SPWM technique operates fixed switching frequency. This is done by injecting equal but opposite current to shape the pulsating supply current to a sinusoidal form and in time phase with the supply voltage. Consequently, it would reduced input current distortion and achieve unity power factor when feeding a nonlinear load.

Keywords- Shunt Active Power Filter (SAPF), Hysteresis Current Controller (HCC), Voltage Source Inverter (VSI), Hysteresis Band (HB), Synchronous Reference Frame (SRF), Sinusoidal Pulse Width Modulation (SPWM), Total Harmonics Distortion (%THD), Switching Frequency
Publication Details
Unique Identification Number - IJEDR1702282
Page Number(s) - 1795-1802
Pubished in - Volume 5 | Issue 2 | June 2017
DOI (Digital Object Identifier) -   
Publisher - IJEDR (ISSN - 2321-9939)
Cite this Article
  Mr. Shashibhushan R. Shahu ,  Mr. Nikhil A. Wanjari,   "Performance Analysis of Shunt Active Power Filter with Various Switching Signal Generation Techniques", International Journal of Engineering Development and Research (IJEDR), ISSN:2321-9939, Volume.5, Issue 2, pp.1795-1802, June 2017, Available at :http://www.ijedr.org/papers/IJEDR1702282.pdf